• Newsroom
  • Contact
  • safe&easy
  • DE EN 中文
results out of Read more Products View all results

Share

Share this page

You can share this page with others by sending the URL of the selected page.

Email LinkedIn
DC12 Screw-on mounting from front side en 12708
Screw-on mounting
from front side
DC12 Snap-in version from front side en 12707
Snap-in version
from front side
DC12 Screw-on mounting from front side  protection class II en 93167
Screw-on mounting
from front side, protection class II
DC12 Screw-on mounting from rear side en 12706
Screw-on mounting
from rear side
DC12 Screw-on mounting from front side en 12708
DC12 Snap-in version from front side en 12707
DC12 Screw-on mounting from front side  protection class II en 93167
DC12 Screw-on mounting from rear side en 12706

Series: DC12

Free Sample Request

IEC Appliance Inlet C14 with Filter, Line Switch 1- or 2-pole, Front or Rear Side Mounting

81 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C
C18
Connector Logo
70° C

Description DC12

Description

  • Panel mount: Screw-on version from front or rear side, snap-in version from front side
  • 3 Functions: Appliance Inlet protection class I or II, Line Switch 1  or 2 pole, Line filter in standard and medical version
  • Quick connect terminals 6.3 x 0.8 mm

Unique Selling Proposition

  • Compact power entry module
  • Available in white or black
  • Switch for high inrush current
  • V-Lock cord retaining

Characteristics

  • Compact design with optimal shielding
    Rear side mounting for efficient costsaving assembly
  • All single elements are already wired
  • Line switch non-illuminated or illuminated
  • Universal line filter for standard applications
  • Ideal for application with high transient loads
  • Suitable for use in equipment according to IEC/UL 60950
    Suitable for use in medical equipment according to IEC/UL 60601-1

Other versions on request

  • Solder terminals
  • Other rocker marking
  • Capacitance CX1

Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

Date Subcategory Language Title Download
30/10/2018
PCS English DC12 Product Content Sheet
09/08/2018
Flyers English Flyer V-Lock cord-retention safeguard
09/08/2018
White Paper English White Paper Cord retention
13/07/2018
PCN English All connectors PG06 PCN Change of configuration code PG06
06/04/2018
White Paper English White Paper Mating Connectors English
08/03/2018
Flyers English Flyer Components and Solutions for Medical Equipment
08/03/2018
PCN English DC12 PCN New approval mark for CQC
08/01/2018
PCN English DC12 PCN
24/11/2017
White Paper English White Paper Leakage currents
09/09/2017
White Paper English White Paper Power Consumption
27/02/2017
PCS English DC12 1-pole, Snap-in PCS
20/04/2016
PCS English DC12 Product Content Sheets
20/04/2016
PCS English DC12 Product Content Sheet

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.

Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.


Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.

Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.

The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.

Details about IP protection degree can be looked up in the general product information

IP-Protection

from front side IP 40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information


Insulation cover

Suitable for appliances with protection class I or II acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.

Terminal

Quick connect terminals 6.3 x 0.8 mm

Panel Thickness S

Panel Thickness S



See details in drawing

Snapper

Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1 mm to 3 mm

Material: Housing

Thermoplastic, black / white, UL 94V-0

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information

Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

C14 / C18 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II

Line Switch

Fuse holder


1.) fuse holder does not include circuit breakers

2.) Details about fuse-links can be found in the catalog under Non-Resettable Fuses

Detailed information on the fuse holder and fuse drawers can be found in the general product information.

Fuse drawer

Rocker switch 1 or 2 pole, non-illuminated or illuminated, acc. to IEC 61058-1
Technical Details

Line Filter

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.

MTBF

> 1'900'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  
Details about Approvals


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: DC12

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40001522
Approval marks cURus UL UL File Number: E72928
Approval marks CQC CQC CCC Certificate Number: CQC18001188116


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG EU Directive RoHS 2011/65/EU
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
 V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

DC12
DC12.1102.001 DC12.1102.003 DC12.1122.001 DC12.1122.003 DC12.1132.001 DC12.1132.003 DC12.1202.001 DC12.1202.003 DC12.1222.001 DC12.1222.003 DC12.1232.001 DC12.1232.003 DC12.2102.001 DC12.2102.003 DC12.2122.001 DC12.2122.003 DC12.2132.001 DC12.2132.003 DC12.2202.001 DC12.2202.003 DC12.2222.001 DC12.2222.003 DC12.2232.001 DC12.2232.003 DC12.3102.001 DC12.3102.003 DC12.3122.001 DC12.3122.003 DC12.3132.001 DC12.3132.003 DC12.3202.001 DC12.3202.003 DC12.3222.001 DC12.3222.003 DC12.3232.001 DC12.3232.003 DC12.3802.001 DC12.4102.001 DC12.4102.003 DC12.4122.001 DC12.4122.003 DC12.4132.001 DC12.4132.003 DC12.4202.001 DC12.4202.003 DC12.4222.001 DC12.4222.003 DC12.4232.001 DC12.4232.003 DC12.5102.001 DC12.5102.003 DC12.5122.001 DC12.5122.003 DC12.5132.001 DC12.5132.003 DC12.5202.001 DC12.5202.003 DC12.5222.001 DC12.5222.003 DC12.5232.001 DC12.5232.003
DC12.XXXX.00X DC12.XXXX.01X CAD-Model shows variation with switch non illuminated, terminal 6.3x0.8 mm
DC12
DC12.1102.101 DC12.1102.103 DC12.1122.101 DC12.1122.103 DC12.1132.101 DC12.1132.103 DC12.1202.101 DC12.1202.103 DC12.1222.101 DC12.1222.103 DC12.1232.101 DC12.1232.103 DC12.2102.101 DC12.2102.103 DC12.2122.101 DC12.2122.103 DC12.2132.101 DC12.2132.103 DC12.2202.101 DC12.2202.103 DC12.2222.101 DC12.2222.103 DC12.2232.101 DC12.2232.103 DC12.3102.101 DC12.3102.103 DC12.3122.101 DC12.3122.103 DC12.3132.101 DC12.3132.103 DC12.3202.101 DC12.3202.103 DC12.3222.101 DC12.3222.103 DC12.3232.101 DC12.3232.103 DC12.4102.101 DC12.4102.103 DC12.4122.101 DC12.4122.103 DC12.4132.101 DC12.4132.103 DC12.4202.101 DC12.4202.103 DC12.4222.101 DC12.4222.103 DC12.4232.101 DC12.4232.103 DC12.5102.101 DC12.5102.103 DC12.5122.101 DC12.5122.103 DC12.5132.101 DC12.5132.103 DC12.5202.101 DC12.5202.103 DC12.5222.101 DC12.5222.103 DC12.5232.101 DC12.5232.103
DC12.XXXX.10X DC12.XXXX.11X CAD-Model shows variation with switch non illuminated, terminal 6.3x0.8 mm
DC12
DC12.5202.121 DC12.5202.131 DC12.1202.121 DC12.1202.131 DC12.2202.121 DC12.2202.131 DC12.3202.121 DC12.3202.131 DC12.4202.121 DC12.4202.131
DC12.XXXX.12X DC12.XXXX.13X CAD-Model shows variation with switch non illuminated, terminal 6.3x0.8 mm
DC12
DC12.1202.021 DC12.1202.031 DC12.2202.021 DC12.2202.031 DC12.3202.021 DC12.3202.031 DC12.4202.021 DC12.4202.031 DC12.5202.021 DC12.5202.031
DC12.XXXX.02X DC12.XXXX.03X CAD-Model shows variation with switch non illuminated, terminal 6.3x0.8 mm
DC12
DC12.XXXX.22X DC12.XXXX.23X CAD-Model shows variation with switch non illuminated, terminal 6.3x0.8 mm
DC12
DC12.1102.201 DC12.1102.203 DC12.1202.201 DC12.1602.201 DC12.2102.201 DC12.2102.203 DC12.2202.201 DC12.2602.201 DC12.3102.201 DC12.3102.203 DC12.3202.201 DC12.3602.201 DC12.4102.201 DC12.4102.203
DC12.XXXX.20X DC12.XXXX.21X CAD-Model shows variation with switch non illuminated, terminal 6.3x0.8 mm

Dimensions [mm]

Screw-on mounting from front side

Screw-On Version from rear side (metal flange)

Snap-in mounting from front side

Screw-on mounting from front side (protection class II)

Screw-on version from rear side (protection class II)

Snap-in mounting from front side (protection class II)


Diagrams

Standard filter 1-pole

1) Line
2) Load
Standard filter 2-pole

1) Line
2) Load
Medical filter 1-pole (M5)

1) Line
2) Load
Medical filter 2-pole (M5)

1) Line
2) Load
Standard filter 2-pole
illuminated
1) Line
2) Load
Medical Filter 2-pole (M5)
illuminated
1) Line
2) Load
Medical filter 2-pole (M5) protection class II

1) Line
2) Load

Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
1 Standard Version 2 x 10 100 2.2 1
2 Standard Version 2 x 4 100 2.2 1
4 Standard Version 2 x 1.5 100 2.2 1
6 Standard Version 2 x 0.8 100 2.2 1
10 Standard Version 2 x 0.3 100 2.2 1
1 Medical Version (M5) 2 x 10 100 - 1
2 Medical Version (M5) 2 x 4 100 - 1
4 Medical Version (M5) 2 x 1.5 100 - 1
6 Medical Version (M5) 2 x 0.8 100 - 1
10 Medical Version (M5) 2 x 0.3 100 - 1
1 Medical Version (M80) 2 x 10 100 0.47 1
2 Medical Version (M80) 2 x 4 100 0.47 1
4 Medical Version (M80) 2 x 1.5 100 0.47 1
6 Medical Version (M80) 2 x 0.8 100 0.47 1
10 Medical Version (M80) 2 x 0.3 100 0.47 1

Attenuation Loss

1 A

2 A

4 A

6 A

10 A

1 A

2 A

4 A

6 A

10 A


Short Table of Variants DC12


Rated current

Rated current


Max. rated current according to IEC vs. UL/CSA- approval for the listed type.
Further details see data sheet

Filter-Type

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Panel mounting

Panel mounting


The mounting method describes the mounting of the component into the housing.

Mounting

Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:

Contact-Form
Availability for all products can be searched real-time. Enter part number and required quantity:

Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check

Stock Check Distributor

...
[A]                
 
1 Standard Version Snap-in DC12.1102.103 ...
2 Standard Version Snap-in DC12.2102.103 ...
4 Standard Version Snap-in DC12.3102.103 ...
6 Standard Version Snap-in DC12.4102.103 ...
10 Standard Version Snap-in DC12.5102.103 ...
1 Standard Version Snap-in DC12.1102.101 ...
2 Standard Version Snap-in DC12.2102.101  A  ...
4 Standard Version Snap-in DC12.3102.101  A  ...
6 Standard Version Snap-in DC12.4102.101  A  ...
10 Standard Version Snap-in DC12.5102.101  A  ...
1 Standard Version Screw DC12.1102.003 ...
2 Standard Version Screw DC12.2102.003 ...
4 Standard Version Screw DC12.3102.003 ...
6 Standard Version Screw DC12.4102.003  A  ...
10 Standard Version Screw DC12.5102.003  A  ...
1 Standard Version Screw DC12.1102.001  A  ...
2 Standard Version Screw DC12.2102.001  A  ...
4 Standard Version Screw DC12.3102.001  A  ...
6 Standard Version Screw DC12.4102.001  A  ...
10 Standard Version Screw DC12.5102.001  A  ...
1 Standard Version Screw DC12.1102.203 ...
2 Standard Version Screw DC12.2102.203 ...
4 Standard Version Screw DC12.3102.203 ...
6 Standard Version Screw DC12.4102.203 ...
10 Standard Version Screw DC12.5102.203 ...
1 Standard Version Screw DC12.1102.201 ...
2 Standard Version Screw DC12.2102.201 ...
4 Standard Version Screw DC12.3102.201 ...
6 Standard Version Screw DC12.4102.201 ...
10 Standard Version Screw DC12.5102.201 ...
1 Medical Version (M5) Snap-in DC12.1202.103 ...
2 Medical Version (M5) Snap-in DC12.2202.103 ...
4 Medical Version (M5) Snap-in DC12.3202.103 ...
6 Medical Version (M5) Snap-in DC12.4202.103 ...
10 Medical Version (M5) Snap-in DC12.5202.103 ...
1 Medical Version (M5) Snap-in DC12.1202.101 ...
1 Medical Version (M5) Snap-in DC12.1202.121 ...
1 Medical Version (M5) Snap-in DC12.1202.131 ...
2 Medical Version (M5) Snap-in DC12.2202.101 ...
2 Medical Version (M5) Snap-in DC12.2202.121 ...
2 Medical Version (M5) Snap-in DC12.2202.131 ...
4 Medical Version (M5) Snap-in DC12.3202.101 ...
4 Medical Version (M5) Snap-in DC12.3202.121 ...
4 Medical Version (M5) Snap-in DC12.3202.131 ...
6 Medical Version (M5) Snap-in DC12.4202.101 ...
6 Medical Version (M5) Snap-in DC12.4202.121 ...
6 Medical Version (M5) Snap-in DC12.4202.131 ...
10 Medical Version (M5) Snap-in DC12.5202.101 ...
10 Medical Version (M5) Snap-in DC12.5202.121 ...
10 Medical Version (M5) Snap-in DC12.5202.131 ...
6 Medical Version (M5) Snap-in DC12.4232.101 ...
1 Medical Version (M5) Screw DC12.1202.003 ...
2 Medical Version (M5) Screw DC12.2202.003 ...
4 Medical Version (M5) Screw DC12.3202.003 ...
6 Medical Version (M5) Screw DC12.4202.003 ...
10 Medical Version (M5) Screw DC12.5202.003 ...
1 Medical Version (M5) Screw DC12.1202.001 ...
1 Medical Version (M5) Screw DC12.1202.021 ...
1 Medical Version (M5) Screw DC12.1202.031 ...
2 Medical Version (M5) Screw DC12.2202.001 ...
2 Medical Version (M5) Screw DC12.2202.021 ...
2 Medical Version (M5) Screw DC12.2202.031 ...
4 Medical Version (M5) Screw DC12.3202.001 ...
4 Medical Version (M5) Screw DC12.3202.021 ...
4 Medical Version (M5) Screw DC12.3202.031 ...
6 Medical Version (M5) Screw DC12.4202.001 ...
6 Medical Version (M5) Screw DC12.4202.021 ...
6 Medical Version (M5) Screw DC12.4202.031 ...
10 Medical Version (M5) Screw DC12.5202.001 ...
10 Medical Version (M5) Screw DC12.5202.021 ...
10 Medical Version (M5) Screw DC12.5202.031 ...
1 Medical Version (M5) Screw DC12.1202.201 ...
2 Medical Version (M5) Screw DC12.2202.201 ...
4 Medical Version (M5) Screw DC12.3202.201 ...
6 Medical Version (M5) Screw DC12.4202.201 ...
10 Medical Version (M5) Screw DC12.5202.201 ...
1 Medical Version (M80) Screw DC12.1602.201 ...
2 Medical Version (M80) Screw DC12.2602.201 ...
4 Medical Version (M80) Screw DC12.3602.201 ...
6 Medical Version (M80) Screw DC12.4602.201 ...
10 Medical Version (M80) Screw DC12.5602.201 ...

Most Popular.


Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Substitute for type (2)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (21)

[Swipe to the left and right for more options]

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

IEC Connector C15 for hot conditions 120°C, Rewireable, Straight

4784

IEC Connector C15 for hot conditions 120°C, Rewireable, Angled

6007.0212

Cord Sets 10 A, Interconnection, 1.0 m, Connector IEC C13, H05VV-F3G1.0, black

6007.0214

Cord Sets 10 A, Interconnection, 2.0 m, Connector IEC C13, H05VV-F3G1.0, black

6004.0114

Cord Sets 10 A, Europlug, 2.0 m, Connector IEC C13, H05VV-F3G0.75, black

6004.0215

Cord Sets 10 A, Europlug, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black

6003.0215

Cord Sets 10 A, Europlug, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black

6004.0225

Cord Sets 10 A, Europlug, Black, 2.5 m, H05VV-F 3G1,0mm2, Connector IEC C13, 002500 mm, H05VV-F3G1.0, black

6052.0026

Cord Sets 10 A, diverse, Black, 5.0 m, H05VV-F 3G1,0mm2, Connector IEC C13, 002500 mm, H05VV-F3G1.0, black

6000.0224

Cord Sets 10 A, uninsulated wires, 2.0 m, Connector IEC C13, H05VV-F3G1.0, black

6000.0214

Cord Sets 10 A, uninsulated wires, 2.0 m, Connector IEC C13, H05VV-F3G1.0, black

6044.0215

Cord Sets 10 A, United Kingdom, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black

6043.0114

Cord Sets 10 A, United Kingdom, 2.0 m, Connector IEC C13, H05VV-F3G0.75, black

6026.0215

Cord Sets 10 A, Italy, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black

6011.0215

Cord Sets 10 A, Switzerland, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black

6009.1214

Cord Sets 10 A, North America, 2.0 m, Connector IEC C13, SVT 3x18 AWG, black

6009.1315

Cord Sets 10 A, North America, 2.5 m, Connector IEC C13, SJT 3x18 AWG, black

6047.6414

Cord Sets 10 A, Japan, 2.0 m, Connector IEC C13, HVCTF3G0.75, black

Mating Outlets/Connectors shuttered (2)

[Swipe to the left and right for more options]

VAC13KS

VAC13KS, Overview, diverse Connector IEC C13, cord end:

VAC17KS

Power cord with IEC connector C17, V-Lock, straight

Accessories (4)

[Swipe to the left and right for more options]

Wire Harness

Wire harness for SCHURTER products

Cord retaining kits

Cord retaining strain relief

4700.0001

Flat head, A

4700.0002

Countersunk, B


uk.schurter.com
en
en
prod //cdn.schurter.com